Glass Capsule Anchors VDP-UW/1,5t

Glass Capsule Anchors VDP-UW/1,5t

From

Starting at €42.60

Spin Type glass capsule anchor specially designed for the installation of Threaded Rods in marine applications

Features

  • For Underwater installation
  • Ideal for Fender Installation, Water Purification and Desalination Plants
  • Reinforcing Jetties
  •  NO CHEMICAL OR PLASTIC WASTE 
    Just a cardboard box ready to be recycled!
View versions and order

Versions

Grouped product items
Quantity Art.no. Description Qty. EAN Price excl. VAT
3900217V VDP-UW M16/1,5t 10 8714345156194 €42.60
3900221V VDP-UW M20/1,5t 6 8714345156200 €51.06
3900225V VDP-UW M24/1,5t 6 8714345156217 €59.10

Installation Procedures

Product Dimensions

Anchor Size

Da

[mm]

M16

M20

M24

Anchor Rod Length

La≥

[mm]

255

335

410

Capsule Type

VDP-UW

 

M16/1,5t

M20/1,5t

M24/1,5t

Capsule Diameter

Dp

[mm]

17

17

22

Capsule Length

Lp

[mm]

125

255

245

Capsule Volume

Vp

[cc]

23,1

76,0

106,0

Required Volume/cm

Vs

[cc/cm]

0,95

2,40

2,54

Steel Brush Diameter

D

[mm]

20

24

28

Min. Brush Diameter

Dmin

[mm]

18,5

18,5

26,5

 

Installation Dimensions

Anchor Size

Da

[mm]

M16

M20

M24

Hole Diameter

d0

[mm]

18

22

26

Embedment Depth

h0=hef

[mm]

190

255

315

Diameter Fixture Hole

df

[mm]

18

22

26

Fixture Height

tfix≤

[mm]

40

50

50

Recommended Torque

Tinst

[Nm]

80

120

150

 

Member Thickness, Edge Distance & Spacing

Anchor Size

Da

[mm]

M16

M20

M24

Min. Member Thickness

hmin

[mm]

225

300

370

Min. Edge Distance

Cmin

[mm]

95

130

160

Min. Spacing

Smin

[mm]

95

130

160

 

Curing Times

Concrete Temperature

Min. Curing Time in Dry Holes

Min. Curing Time in Wet Holes

≥ -5˚C

5 hrs

10 hrs

≥ +5˚C

1 hr

2 hrs

≥ +20˚C

20 min

40 min

≥ +30˚C

10 min

20 min