VDP Quartz M24
VDP Quartz M24
VD-Quartz is a spin type, Vinylester based, glass capsule anchor with ETA Assessment, option 1 for cracked and non-cracked concrete
Features
- Increased Load Bearing Capacity
- Simplified Cleaning Procedures
- Easy Installation
- Fast Curing
- Available in 1,5t Capsules
- F120 Fire Rating
- VOC Rating: A+
- Zero Chemical or Plastic Wastage
- B+BTEC DesignFix® Support
Part Nr. 3900324V
EAN: 8714345149585
Qty./Box: 10
Installation Procedures
Product Dimensions
Anchor Size |
Da |
[mm] |
M24 |
Anchor Rod Length |
La≥ |
[mm] |
300 |
Capsule Type |
VDP |
|
M24 |
Capsule Diameter |
Dp |
[mm] |
22 |
Capsule Length |
Lp |
[mm] |
175 |
Capsule Volume |
Vp |
[cc] |
52,6 |
Required Volume/cm |
Vs |
[cc/cm] |
2,01 |
Steel Brush Diameter |
D |
[mm] |
28 |
Min. Brush Diameter |
Dmin |
[mm] |
26,5 |
Installation Dimensions
Anchor Size |
Da |
[mm] |
M24 |
Hole Diameter |
d0 |
[mm] |
26 |
Embedment Depth |
h0=hef |
[mm] |
210 |
Diameter Fixture Hole |
df |
[mm] |
26 |
Fixture Height |
tfix≤ |
[mm] |
56 |
Recommended Torque |
Tinst |
[Nm] |
180 |
Member Thickness, Edge Distance & Spacing
Anchor Size |
Da |
[mm] |
M24 |
Min. Member Thickness |
hmin |
[mm] |
260 |
Min. Edge Distance |
Cmin |
[mm] |
105 |
Min. Spacing |
Smin |
[mm] |
105 |
Curing Times
Concrete Temperature |
Min. Curing Time in Dry Holes |
Min. Curing Time in Wet Holes |
≥ -5˚C |
5 hrs |
10 hrs |
≥ +5˚C |
1 hr |
2 hrs |
≥ +20˚C |
20 min |
40 min |
≥ +30˚C |
10 min |
20 min |