DRILLING + ANCHORING TECHNOLOGY WITH A BIG PLUS!
BIS-V Vinylester 300 ml
€ 30,20 excl. VAT
Injection mortar ETA Option 1 for cracked concrete
In stock
Need a larger quantity or working on a bigger project? request a quote.
Installation Procedures

Installation Dimensions
For Installation Dimensions and Loads please refer to the Technical Data Sheets (TDS) or European Technical Assessment (ETA) under Downloads.
Curing times
Cartridge Temperature should be min. +15˚C. For damp bore holes the curing time should be doubled.
| Concrete temperature ˚C | Processing time | Dry Drill holes |
| ≥ -10 | 90 min | 24 hrs |
| ≥ -5 | 90 min | 14 hrs |
| ≥ 0 | 45 min | 7 hrs |
| ≥ +5 | 25 min | 2 hrs |
| ≥ +10 | 15 min | 80 min |
| ≥ +20 | 6 min | 45 min |
| ≥ +30 | 4 min | 25 min |
| ≥ +35 | 2 min | 20 min |
| ≥ +40 | 1.5 min | 15 min |